pentetic acid - Medications

Browse 2 medications containing pentetic acid. Open a product record to review formulation details, related brands, manufacturers, and label-backed information.

DRAXIMAGE DTPA KIT FOR THE PREPARATION OF TECHNETIUM TC 99M PENTETATE
JUBILANT DRAXIMAGE INC., DBA JUBILANT RADIOPHARMA FDA Rx Only

11.1 Chemical Characteristics DRAXIMAGE ® DTPA is a kit for the preparation of Technetium Tc 99m pentetate injection, a radioactive diagnostic agent, for intravenous or inhalation use. Each multiple-dose 10 mL glass vial contains a sterile, non-pyrogenic, non-radioactive lyophilized powder of 20 mg of pentetic acid, 5 mg of p-aminobenzoic acid, 3.73 mg of calcium chloride dihydrate, and not less than 0.25 mg stannous chloride dihydrate and not more than 0.385 mg maximum tin expressed as stannous chloride dihydrate. The lyophilized product is sealed under an atmosphere of nitrogen. No bacteriostatic preservative is present. Its chemical name is: Technetate (1-)99mTc,[N,N-bis[2-[bis(carboxymethyl)amino]ethyl]-glycinato(5-)]-, sodium. The structure of the technetium labeled form is: The pH is adjusted with HCl and/or NaOH prior to lyophilization so that the pH range of the reconstituted radiopharmaceutical is 6.5 to 7.5. structure 11.2 Physical Characteristics Technetium Tc 99m decays by isomeric transition with a physical half-life of 6 hours. The principal photon that is useful for detection and imaging studies is listed in Table 7 . Table 7 Principal Radiation Emission Data Radiation Mean % per Disintegration Mean Energy (keV) Gamma-2 88.5 140.5 The air-kerma-rate (exposure-rate) constant for Technetium Tc 99m is 5.23 m 2 ·pGy·(MBq) − 1 ·s − 1 [0.795 cm 2 ·R·(mCi) − 1 ·h − 1 ]. A range of values for the relative radiation attenuation by the various thicknesses of lead is shown in Table 8 . For example, the use of a 3 mm thickness of lead will attenuate the radiation emitted by a factor of about 1,000. Table 8 Radiation Attenuation by Lead Shielding Shield Thickness (Pb) cm Coefficient of Attenuation 0.25 0.5 1 10 -1 2 10 -2 3 10 -3 4 10 -4 To correct for physical decay of this radionuclide, the fractions that remain at selected intervals after the time of calibration are shown in Table 9 . Table 9 Physical Decay Chart of Technetium 99m Tc, Half Life: 6 Hours *Calibration Time Hours Fraction Remaining Hours Fraction Remaining 0 * 1.000 5 0.562 1 0.891 6 0.501 2 0.794 8 0.398 3 0.708 10 0.316 4 0.631 12 0.251

Kit for the Preparation of Technetium Tc 99m Pentetate KIT FOR THE PREPARATION OF TECHNETIUM TC 99M PENTETATE
CURIUM US LLC FDA Rx Only

11.1 Chemical Characteristics Kit for the Preparation of Technetium Tc 99m pentetate injection, a radioactive diagnostic agent, for intravenous or inhalation use. Each multiple-dose 10 mL glass vial contains a sterile, non-pyrogenic, non-radioactive lyophilized powder of 20 mg of pentetic acid, 5 mg of p-aminobenzoic acid, 3.73 mg of calcium chloride dihydrate, and not less than 0.25 mg stannous chloride dihydrate and not more than 0.385 mg maximum tin expressed as stannous chloride dihydrate. The lyophilized product is sealed under an atmosphere of nitrogen. No bacteriostatic preservative is present. Its chemical name is: Technetate (1-)99mTc,[N,N-bis[2-[bis(carboxymethyl)amino]ethyl]-glycinato(5-)]-, sodium. The structure of the technetium labeled form is: The pH is adjusted with HCl and/or NaOH prior to lyophilization so that the pH range of the reconstituted radiopharmaceutical is 6.5 to 7.5. image description 11.2 Physical Characteristics Technetium Tc 99m decays by isomeric transition with a physical half-life of 6 hours. The principal photon that is useful for detection and imaging studies is listed in Table 7 . Table 7 Principal Radiation Emission Data Radiation Mean % per Disintegration Mean Energy (keV) Gamma-2 88.5 140.5 The air-kerma-rate (exposure-rate) constant for Technetium Tc 99m is 5.23m 2 ·pGy·(MBq) -1 ·s -1 [0.795cm 2 ·R·(mCi) -1 ·h -1 ]. A range of values for the relative radiation attenuation by the various thicknesses of lead is shown in Table 8 . For example, the use of a 3 mm thickness of lead will attenuate the radiation emitted by a factor of about 1,000. Table 8 Radiation Attenuation by Lead Shielding Shield Thickness (Pb) mm Coefficient of Attenuation 0.25 0.5 1 10 -1 2 10 -2 3 10 -3 4 10 -4 To correct for physical decay of this radionuclide, the fractions that remain at selected intervals after the time of calibration are shown in Table 9 . Table 9 Physical Decay Chart of Technetium 99m Tc, Half Life: 6 Hours Hours Fraction Remaining Hours Fraction Remaining 0* 1.000 5 0.562 1 0.891 6 0.501 2 0.794 8 0.398 3 0.708 10 0.316 4 0.631 12 0.251 *Calibration Time

About pentetic acid

This collection groups medications in our database that include pentetic acid. It currently includes 2 matching listings. Open a result to review formulation details, related brands, manufacturers, and product labels.

What You Can Review

Use this page to find products that share the same indexed ingredient name, then open drug detail pages for dosage, labeling, and related navigation.

Safety Information

Always consult with a qualified healthcare provider before starting, stopping, or changing any medication. The information provided on this page is for educational purposes only and does not constitute medical advice.