ucsf radiopharmaceutical facility - Medication Listings
Browse 3 medications manufactured by ucsf radiopharmaceutical facility. Open a product record to review dosage forms, strengths, packaging, and related navigation.
11.1 Chemical Characteristics Ammonia N 13 Injection is a positron emitting radiopharmaceutical that is used for diagnostic purposes in conjunction with positron emission tomography (PET) imaging. The active ingredient, [ 13 N] ammonia, has the molecular formula of 13 NH 3 with a molecular weight of 16.02, and has the following chemical structure: Ammonia N 13 Injection is provided as a ready to use sterile, pyrogen-free, clear and colorless solution. Each mL of the solution contains between 0.138 GBq to 1.387 GBq (3.75 mCi to 37.5mCi) of [ 13 N] ammonia, at the end of synthesis (EOS) reference time, in 0.9% aqueous sodium chloride. The pH of the solution is between 4.5 to 7.5.The recommended dose of radioactivity (10-20 mCi) is associated with a theoretical mass dose of 0.5-1.0 picomoles of ammonia. image description 11.2 Physical Characteristics Nitrogen N13 decays by emitting positron to Carbon C13 (stable) and has a physical half-life of 9.96 minutes. The principal photons useful for imaging are the dual 511 keV gamma photons that are produced and emitted simultaneously in opposite direction when the positron interacts with an electron (Table 2). Table 2: Principal Radiation Emission Data for Nitrogen 13 Radiation/Emission % Per Disintegration Energy Positron(β+) 100 1190 keV (Max.) Gamma(±)* 200 511 keV *Produced by positron annihilation The specific gamma ray constant (point source air kerma coefficient) for nitrogen N13 is 5.9 R/hr/mCi (1.39 x 10 -6 Gy/hr/kBq) at 1 cm. The half-value layer (HVL) of lead (Pb) for 511 keV photons is 4 mm. Selected coefficients of attenuation are listed in Table 3 as a function of lead shield thickness. For example, the use of 39 mm thickness of lead will attenuate the external radiation by a factor of about 1000. Table 3: Radiation Attenuation of 511 keV Photons by lead (Pb) shielding Shield Thickness (Pb) mm Coefficient of Attenuation 4 0.5 8 0.25 13 0.1 26 0.01 39 0.001 52 0.0001 Table 4 lists fractions remaining at selected time intervals from the calibration time. This information may be used to correct for physical decay of the radionuclide. Table 4: Physical Decay Chart for Nitrogen N 13 Minutes Fraction Remaining 0* 1.000 5 0.706 10 0.499 15 0.352 20 0.249 25 0.176 30 0.124 *Calibration time 11.1 Chemical Characteristics Ammonia N 13 Injection is a positron emitting radiopharmaceutical that is used for diagnostic purposes in conjunction with positron emission tomography (PET) imaging. The active ingredient, [ 13 N] ammonia, has the molecular formula of 13 NH 3 with a molecular weight of 16.02, and has the following chemical structure: Ammonia N 13 Injection is provided as a ready to use sterile, pyrogen-free, clear and colorless solution. Each mL of the solution contains between 0.138 GBq to 1.387 GBq (3.75 mCi to 37.5mCi) of [ 13 N] ammonia, at the end of synthesis (EOS) reference time, in 0.9% aqueous sodium chloride. The pH of the solution is between 4.5 to 7.5.The recommended dose of radioactivity (10-20 mCi) is associated with a theoretical mass dose of 0.5-1.0 picomoles of ammonia. image description 11.2 Physical Characteristics Nitrogen N13 decays by emitting positron to Carbon C13 (stable) and has a physical half-life of 9.96 minutes. The principal photons useful for imaging are the dual 511 keV gamma photons that are produced and emitted simultaneously in opposite direction when the positron interacts with an electron (Table 2). Table 2: Principal Radiation Emission Data for Nitrogen 13 Radiation/Emission % Per Disintegration Energy Positron(β+) 100 1190 keV (Max.) Gamma(±)* 200 511 keV *Produced by positron annihilation The specific gamma ray constant (point source air kerma coefficient) for nitrogen N13 is 5.9 R/hr/mCi (1.39 x 10 -6 Gy/hr/kBq) at 1 cm. The half-value layer (HVL) of lead (Pb) for 511 keV photons is 4 mm. Selected coefficients of attenuation are listed in Table 3 as a function of lead shield thickness. For example, the use of 39 mm thickness of lead will attenuate the external radiation by a factor of about 1000. Table 3: Radiation Attenuation of 511 keV Photons by lead (Pb) shielding Shield Thickness (Pb) mm Coefficient of Attenuation 4 0.5 8 0.25 13 0.1 26 0.01 39 0.001 52 0.0001 Table 4 lists fractions remaining at selected time intervals from the calibration time. This information may be used to correct for physical decay of the radionuclide. Table 4: Physical Decay Chart for Nitrogen N 13 Minutes Fraction Remaining 0* 1.000 5 0.706 10 0.499 15 0.352 20 0.249 25 0.176 30 0.124 *Calibration time
11.1 Chemical Characteristics Fludeoxyglucose F 18 Injection is a positron emitting radiopharmaceutical that is used for diagnostic purposes in conjunction with positron emission tomography (PET) imaging. The active ingredient 2-deoxy-2-[ 18 F]fluoro-D-glucose has the molecular formula of C 6 H 11 18 FO 5 with a molecular weight of 181.26, and has the following chemical structure: Fludeoxyglucose F 18 Injection is provided as a ready to use sterile, pyrogen free, clear, colorless citrate buffered solution. Each mL contains between 0.740 to 11.1GBq (20.0-300 mCi) of 2-deoxy-2-[ 18 F]fluoro-D-glucose at the EOS, 4.5 mg of sodium chloride in citrate buffer. The pH of the solution is between 4.5 and 7.5. The solution is packaged in a multiple-dose glass vial and does not contain any preservative. image of FDG 11.2 Physical Characteristics Fluorine F 18 has a physical half-life of 109.7 minutes and decays to Oxygen O 18 (stable) by positron decay. The principal photons useful for imaging are the dual 511 keV “annihilation” gamma photons that are produced and emitted simultaneously in opposite directions when the positron interacts with an electron (Table 2). Table 2. Principal Radiation Emission Data for Fluorine F 18 Radiation/Emission % Per Disintegration Mean Energy Positron(β+) 96.73 249.8 keV Gamma(±)* 193.46 511.0 keV *Produced by positron annihilation From: Kocher, D.C. Radioactive Decay Tables DOE/TIC-I 1026, 89 (1981) The specific gamma ray constant (point source air kerma coefficient) for fluorine F 18 is 5.7 R/hr/mCi (1.35 x 10 -6 Gy/hr/kBq) at 1 cm. The half-value layer (HVL) for the 511 keV photons is 4 mm lead (Pb). The range of attenuation coefficients for this radionuclide as a function of lead shield thickness is shown in Table 3. For example, the interposition of an 8 mm thickness of Pb, with a coefficient of attenuation of 0.25, will decrease the external radiation by 75%. Table 3. Radiation Attenuation of 511 keV Photons by lead (Pb) shielding Shield thickness (Pb) mm Coefficient of attenuation 0 0.00 4 0.50 8 0.25 13 0.10 26 0.01 39 0.001 52 0.0001 For use in correcting for physical decay of this radionuclide, the fractions remaining at selected intervals after calibration are shown in Table 4. Table 4. Physical Decay Chart for Fluorine F 18 Minutes Fraction Remaining 0* 1.000 15 0.909 30 0.826 60 0.683 110 0.500 220 0.250 *calibration time 11.1 Chemical Characteristics Fludeoxyglucose F 18 Injection is a positron emitting radiopharmaceutical that is used for diagnostic purposes in conjunction with positron emission tomography (PET) imaging. The active ingredient 2-deoxy-2-[ 18 F]fluoro-D-glucose has the molecular formula of C 6 H 11 18 FO 5 with a molecular weight of 181.26, and has the following chemical structure: Fludeoxyglucose F 18 Injection is provided as a ready to use sterile, pyrogen free, clear, colorless citrate buffered solution. Each mL contains between 0.740 to 11.1GBq (20.0-300 mCi) of 2-deoxy-2-[ 18 F]fluoro-D-glucose at the EOS, 4.5 mg of sodium chloride in citrate buffer. The pH of the solution is between 4.5 and 7.5. The solution is packaged in a multiple-dose glass vial and does not contain any preservative. image of FDG 11.2 Physical Characteristics Fluorine F 18 has a physical half-life of 109.7 minutes and decays to Oxygen O 18 (stable) by positron decay. The principal photons useful for imaging are the dual 511 keV “annihilation” gamma photons that are produced and emitted simultaneously in opposite directions when the positron interacts with an electron (Table 2). Table 2. Principal Radiation Emission Data for Fluorine F 18 Radiation/Emission % Per Disintegration Mean Energy Positron(β+) 96.73 249.8 keV Gamma(±)* 193.46 511.0 keV *Produced by positron annihilation From: Kocher, D.C. Radioactive Decay Tables DOE/TIC-I 1026, 89 (1981) The specific gamma ray constant (point source air kerma coefficient) for fluorine F 18 is 5.7 R/hr/mCi (1.35 x 10 -6 Gy/hr/kBq) at 1 cm. The half-value layer (HVL) for the 511 keV photons is 4 mm lead (Pb). The range of attenuation coefficients for this radionuclide as a function of lead shield thickness is shown in Table 3. For example, the interposition of an 8 mm thickness of Pb, with a coefficient of attenuation of 0.25, will decrease the external radiation by 75%. Table 3. Radiation Attenuation of 511 keV Photons by lead (Pb) shielding Shield thickness (Pb) mm Coefficient of attenuation 0 0.00 4 0.50 8 0.25 13 0.10 26 0.01 39 0.001 52 0.0001 For use in correcting for physical decay of this radionuclide, the fractions remaining at selected intervals after calibration are shown in Table 4. Table 4. Physical Decay Chart for Fluorine F 18 Minutes Fraction Remaining 0* 1.000 15 0.909 30 0.826 60 0.683 110 0.500 220 0.250 *calibration time
11.1 Chemical Characteristics Gallium Ga Gozetotide Injection is a radioactive diagnostic agent for intravenous administration. It contains 0.5 mcg/mL Gozetotide, 18.5 MBq/mL to 185 MBq/mL (0.5 mCi/mL to 5 mCi/mL) of gallium Ga gozetotide at calibration time in 0.9% sodium chloride solution with not more than 10% ethanol (approximately 11 mL total volume). Gallium Ga Gozetotide Injection is provided as a sterile, pyrogen free, clear, colorless solution for intravenous use, with a pH between 4.0 and 7.0. Gozetotide is also known as PSMA-11. Gallium Ga Gozetotide is a urea based peptidomimetic that has a covalently bound chelator (HBED-CC). The peptide has the amino acid sequence Glu-NH-CO-NH-Lys(Ahx)-HBED-CC. Gallium Ga Gozeotide has a molecular weight of 1011.91 g/mol and its chemical structure is shown in Figure 1. Figure 1: Chemical Structure of Gallium Ga Gozetotide Chemical Structure 11.2 Physical Characteristics Gallium-68 (Ga 68) decays with a half-life of 68 minutes to stable zinc-68. Table 2 and Table 3 display the principle radiation emission data and physical decay of Ga 68. Table 2: Principal Radiation Emission Data (>1%) for Gallium Ga 68 Radiation/ Emission % Disintegration Mean Energy (MeV) beta+ 88% 0.8360 beta+ 1.1% 0.3526 gamma 178% 0.5110 gamma 3.0% 1.0770 X-ray 2.8% 0.0086 X-ray 1.4% 0.0086 Table 3: Physical Decay Chart for Gallium Ga 68 Minutes Fraction Remaining 0 1 15 0.858 30 0.736 60 0.541 90 0.398 120 0.293 180 0.158 360 0.025 11.3 External Radiation Table 4 displays the radiation attenuation by lead shielding of Ga 68. Table 4: Radiation Attenuation of 511 keV Photons by Lead (Pb) Shielding Shield Thickness (Pb) mm Coefficient of Attenuation 6 0.5 12 0.25 17 0.1 34 0.01 51 0.001
About ucsf radiopharmaceutical facility
This collection groups medications in our database that are associated with ucsf radiopharmaceutical facility. It currently includes 3 matching listings. Open any result to review label-backed details such as dosage forms, ingredients, packaging, and related navigation.
What You Can Review
Use this page to move from manufacturer-level browsing into specific drug detail pages. Each listing gives you a path to the underlying product record and related brand, generic, or substance pages.
Related Navigation
Some products may appear in multiple brand or generic contexts. Check individual listings for the exact naming used in the product data and to continue exploring.
Important Safety Information
Always consult with a qualified healthcare provider before starting, stopping, or changing any medication. The information provided on this page is for educational purposes only and does not constitute medical advice. Read medication labels and package inserts carefully before use.