the regents of the university of michigan - Medication Listings

Browse 1 medications manufactured by the regents of the university of michigan. Open a product record to review dosage forms, strengths, packaging, and related navigation.

Fludeoxyglucose F18 FLUDEOXYGLUCOSE F18
4.5 mg Injection
THE REGENTS OF THE UNIVERSITY OF MICHIGAN FDA Rx Only

11.1 Chemical Characteristics Fludeoxyglucose F 18 Injection is a positron emitting radiopharmaceutical that is used for diagnostic purposes in conjunction with positron emission tomography (PET) imaging. The active ingredient 2-deoxy-2-[ 18 F]fluoro-D-glucose has the molecular formula of C 6 H 11 18 FO 5 with a molecular weight of 181.26, and has the following chemical structure: Fludeoxyglucose F 18 Injection is provided as a ready to use sterile, pyrogen free, clear, colorless citrate buffered solution. Each mL contains between 0.037 to 11.1GBq (1-300 mCi) of 2-deoxy-2-[ 18 F]fluoro-D-glucose at the EOS, 4.5 mg of sodium chloride in citrate buffer. The pH of the solution is between 4.5 and 7.5. The solution is packaged in a multiple-dose glass vial and does not contain any preservative. image of FDG 11.2 Physical Characteristics Fluorine F 18 has a physical half-life of 109.7 minutes and decays to Oxygen O 18 (stable) by positron decay. The principal photons useful for imaging are the dual 511 keV “annihilation” gamma photons, that are produced and emitted simultaneously in opposite directions when the positron interacts with an electron (Table 2). Table 2. Principal Radiation Emission Data for Fluorine F 18 Radiation/Emission % Per Disintegration Mean Energy Positron(β+) 96.73 249.8 keV Gamma(±)* 193.46 511.0 keV *Produced by positron annihilation From: Kocher, D.C. Radioactive Decay Tables DOE/TIC-I 1026, 89 (1981) The specific gamma ray constant (point source air kerma coefficient) for fluorine F 18 is 5.7 R/hr/mCi (1.35 x 10 -6 Gy/hr/kBq) at 1 cm. The half-value layer (HVL) for the 511 keV photons is 4 mm lead (Pb). The range of attenuation coefficients for this radionuclide as a function of lead shield thickness is shown in Table 3. For example, the interposition of an 8 mm thickness of Pb, with a coefficient of attenuation of 0.25, will decrease the external radiation by 75%. Table 3. Radiation Attenuation of 511 keV Photons by lead (Pb) shielding Shield thickness (Pb) mm Coefficient of attenuation 0 0.00 4 0.50 8 0.25 13 0.10 26 0.01 39 0.001 52 0.0001 For use in correcting for physical decay of this radionuclide, the fractions remaining at selected intervals after calibration are shown in Table 4. Table 4. Physical Decay Chart for Fluorine F 18 Minutes Fraction Remaining 0* 1.000 15 0.909 30 0.826 60 0.683 110 0.500 220 0.250 *calibration time 11.1 Chemical Characteristics Fludeoxyglucose F 18 Injection is a positron emitting radiopharmaceutical that is used for diagnostic purposes in conjunction with positron emission tomography (PET) imaging. The active ingredient 2-deoxy-2-[ 18 F]fluoro-D-glucose has the molecular formula of C 6 H 11 18 FO 5 with a molecular weight of 181.26, and has the following chemical structure: Fludeoxyglucose F 18 Injection is provided as a ready to use sterile, pyrogen free, clear, colorless citrate buffered solution. Each mL contains between 0.037 to 11.1GBq (1-300 mCi) of 2-deoxy-2-[ 18 F]fluoro-D-glucose at the EOS, 4.5 mg of sodium chloride in citrate buffer. The pH of the solution is between 4.5 and 7.5. The solution is packaged in a multiple-dose glass vial and does not contain any preservative. image of FDG 11.2 Physical Characteristics Fluorine F 18 has a physical half-life of 109.7 minutes and decays to Oxygen O 18 (stable) by positron decay. The principal photons useful for imaging are the dual 511 keV “annihilation” gamma photons, that are produced and emitted simultaneously in opposite directions when the positron interacts with an electron (Table 2). Table 2. Principal Radiation Emission Data for Fluorine F 18 Radiation/Emission % Per Disintegration Mean Energy Positron(β+) 96.73 249.8 keV Gamma(±)* 193.46 511.0 keV *Produced by positron annihilation From: Kocher, D.C. Radioactive Decay Tables DOE/TIC-I 1026, 89 (1981) The specific gamma ray constant (point source air kerma coefficient) for fluorine F 18 is 5.7 R/hr/mCi (1.35 x 10 -6 Gy/hr/kBq) at 1 cm. The half-value layer (HVL) for the 511 keV photons is 4 mm lead (Pb). The range of attenuation coefficients for this radionuclide as a function of lead shield thickness is shown in Table 3. For example, the interposition of an 8 mm thickness of Pb, with a coefficient of attenuation of 0.25, will decrease the external radiation by 75%. Table 3. Radiation Attenuation of 511 keV Photons by lead (Pb) shielding Shield thickness (Pb) mm Coefficient of attenuation 0 0.00 4 0.50 8 0.25 13 0.10 26 0.01 39 0.001 52 0.0001 For use in correcting for physical decay of this radionuclide, the fractions remaining at selected intervals after calibration are shown in Table 4. Table 4. Physical Decay Chart for Fluorine F 18 Minutes Fraction Remaining 0* 1.000 15 0.909 30 0.826 60 0.683 110 0.500 220 0.250 *calibration time

About the regents of the university of michigan

This collection groups medications in our database that are associated with the regents of the university of michigan. It currently includes 1 matching listing.

What You Can Review

Use this page to move from manufacturer-level browsing into specific drug detail pages. Each listing gives you a path to the underlying product record and related brand, generic, or substance pages.

Related Navigation

Some products may appear in multiple brand or generic contexts. Check individual listings for the exact naming used in the product data and to continue exploring.

Important Safety Information

Always consult with a qualified healthcare provider before starting, stopping, or changing any medication. The information provided on this page is for educational purposes only and does not constitute medical advice. Read medication labels and package inserts carefully before use.

Medical Tools & Resources

← Back to search