technetium tc 99m sulfur colloid kit - Generic Medications

Browse 1 brand name versions of technetium tc 99m sulfur colloid kit. Review brand names, dosage forms, strengths, and linked product records.

Kit for the Preparation of Technetium Tc 99m Sulfur Colloid TECHNETIUM TC 99M SULFUR COLLOID KIT
JUBILANT DRAXIMAGE INC., DBA JUBILANT RADIOPHARMA FDA Rx Only

Kit for the Preparation of Technetium Tc 99m Sulfur Colloid Injection contains a Multi-Dose Reaction Vial, a Solution A vial and a Solution B vial which contain the sterile non-pyrogenic, non-radioactive ingredients necessary to produce Technetium Tc 99m Sulfur Colloid Injection for diagnostic use by subcutaneous, intraperitoneal, or intravenous injection or by oral administration. Each 10 mL Multi-Dose Reaction Vial contains, in lyophilized form 2 mg sodium thiosulfate anhydrous, 2.3 mg edetate disodium and 18.1 mg bovine gelatin; a Solution A vial contains 1.8 mL of 0.148 N hydrochloric acid solution and a Solution B vial contains 1.8 mL aqueous solution of 24.6 mg/mL sodium biphosphate anhydrous and 7.9 mg/mL sodium hydroxide. When a solution of sterile and non-pyrogenic Sodium Pertechnetate Tc 99m Injection in isotonic saline is mixed with these components, following the instructions provided with the kit, Technetium Tc 99m Sulfur Colloid Injection is formed. The product is intended for subcutaneous, intraperitoneal, or intravenous injection or for oral administration. The precise structure of Technetium Tc 99m Sulfur Colloid Injection is not known at this time. 11.1 Physical Characteristics Technetium Tc 99m decays by isomeric transition with a physical half-life of 6.02 hours 4 . The principal photon that is useful for detection and imaging studies is listed in Table 7. Table 7. Principal Radiation Emission Data 4 Radiation Mean Percent Per Disintegration Mean Energy (keV) Gamma-2 89.07 140.5 4 Kocher DC: Radioactive decay data tables. DOE/TIC-11026: 108, 1981. 11.2 External Radiation The specific gamma ray constant for Tc 99m is 0.78 R/millicurie-hr at 1cm. The first half-value layer is 0.017 cm of lead (Pb). A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 8. For example, the use of a 0.25 cm thickness of Pb will attenuate the radiation emitted by a factor of about 1,000. Table 8. Radiation Attenuation by Lead Shielding Shield Thickness (Pb) cm Coefficient of Attenuation 0.017 0.5 0.08 10 -1 0.16 10 -2 0.25 10 -3 0.33 10 -4 To correct for physical decay of this radionuclide, the fractions that remain at selected intervals after the time of calibration are shown in Table 9. Table 9. Physical Decay Chart: Tc 99m, half-life 6.02 hours Hours Fraction Remaining Hours Fraction Remaining 0 Calibration time 1.000 6 0.501 1 0.891 7 0.447 2 0.794 8 0.398 3 0.708 9 0.355 4 0.631 10 0.316 5 0.562 11 0.282 - - 12 0.251

About technetium tc 99m sulfur colloid kit Generic Drugs

This collection groups medications in our database under the generic name technetium tc 99m sulfur colloid kit. It currently includes 1 matching listing.

What You Can Review

Use this page to compare the set of products we have indexed for this generic name. Each result links to more detailed product information and related landing pages.

Safety Information

Always consult a qualified healthcare professional before starting, stopping, or switching any medication. The information on this page is educational and should not replace medical advice.

Medical Tools & Resources

← Back to search