technetium tc 99m mertiatide - Generic Medications
Browse 1 brand name versions of technetium tc 99m mertiatide. Review brand names, dosage forms, strengths, and linked product records.
11.1 Chemical Characteristics Kit for the Preparation of Technetium Tc 99m Mertiatide Injection is a sterile, multiple-dose kit for the preparation of technetium Tc 99m mertiatide injection, a radioactive diagnostic agent for intravenous use. The active ingredient, betiatide, is N-[N-[N-[(benzoylthio) acetyl]glycyl]glycyl]-glycine and has a molecular weight of 367.38 g/mol. After reconstitution with sodium pertechnetate Tc 99m injection, the radioactive agent technetium Tc 99m mertiatide (disodium[N-[N-[N- (mercaptoacetyl) glycyl]glycyl] glycinato (2-) - N,N′,N″,S′]oxotechnetate (2-)) is formed in situ. Each 10 mL vial contains 1 mg betiatide, 20 mg lactose monohydrate, 40 mg sodium tartrate dihydrate, 0.07 mg (minimum) stannous chloride dihydrate and 0.2 mg (maximum) total tin expressed as stannous chloride dihydrate. Prior to lyophilization, hydrochloric acid is added for pH adjustment. The vial contents are sealed under argon. After radiolabeling with sodium pertechnetate Tc 99m injection, each vial contains up to 3,700 MBq (100 mCi) of technetium Tc 99m mertiatide in 0.9% sodium chloride injection in approximately 10 mL volume as a sterile, clear, and colorless solution with a pH between 5 and 6. betiatide-chem-stuct tc-99m-mertiatide 11.2 Physical Characteristics Technetium Tc 99m decays by isomeric transition with a physical half-life of 6.02 hours. The principal photon that is useful for detection and imaging is listed in Table 2. Table 2. Principal Radiation Emission Data Radiation M Mean % per Disintegration Energy (keV) Gamma-2 89.07 140.5 To correct for physical decay of the radionuclide, the fractions that remain at selected time intervals after the time of calibration are shown in Table 3. Table 3. Physical Decay Chart: Technetium Tc 99m, Half-life 6.02 Hours Hours Fraction Remaining Hours Fraction Remaining 0* 1.000 7 0.447 1 0.891 8 0.398 2 0.794 9 0.355 3 0.708 10 0.316 4 0.631 11 0.282 5 0.562 12 0.251 6 0.501 * Calibration Time 11.3 External Radiation The specific gamma ray constant for technetium-99m is 0.78 R/mCi-hr at 1 cm. The first half-value thickness of lead (Pb) for technetium-99m is 0.017 cm. The use of 0.25 cm of Pb, for example, will decrease the external radiation exposure by a factor of about 1,000. Table 4 displays the radiation attenuation by lead shielding. Table 4. Radiation Attenuation by Lead Shielding Shield Thickness (Pb) cm Coefficient of Attenuation 0.017 0.5 0.08 10 -1 0.16 10 -2 0.25 10 -3 0.33 10 -4
About technetium tc 99m mertiatide Generic Drugs
This collection groups medications in our database under the generic name technetium tc 99m mertiatide. It currently includes 1 matching listing.
What You Can Review
Use this page to compare the set of products we have indexed for this generic name. Each result links to more detailed product information and related landing pages.
Safety Information
Always consult a qualified healthcare professional before starting, stopping, or switching any medication. The information on this page is educational and should not replace medical advice.