kit for the preparation of technetium tc 99m pentetate - Generic Medications

Browse 2 brand name versions of kit for the preparation of technetium tc 99m pentetate. Review brand names, dosage forms, strengths, and linked product records.

DRAXIMAGE DTPA KIT FOR THE PREPARATION OF TECHNETIUM TC 99M PENTETATE
JUBILANT DRAXIMAGE INC., DBA JUBILANT RADIOPHARMA FDA Rx Only

11.1 Chemical Characteristics DRAXIMAGE ® DTPA is a kit for the preparation of Technetium Tc 99m pentetate injection, a radioactive diagnostic agent, for intravenous or inhalation use. Each multiple-dose 10 mL glass vial contains a sterile, non-pyrogenic, non-radioactive lyophilized powder of 20 mg of pentetic acid, 5 mg of p-aminobenzoic acid, 3.73 mg of calcium chloride dihydrate, and not less than 0.25 mg stannous chloride dihydrate and not more than 0.385 mg maximum tin expressed as stannous chloride dihydrate. The lyophilized product is sealed under an atmosphere of nitrogen. No bacteriostatic preservative is present. Its chemical name is: Technetate (1-)99mTc,[N,N-bis[2-[bis(carboxymethyl)amino]ethyl]-glycinato(5-)]-, sodium. The structure of the technetium labeled form is: The pH is adjusted with HCl and/or NaOH prior to lyophilization so that the pH range of the reconstituted radiopharmaceutical is 6.5 to 7.5. structure 11.2 Physical Characteristics Technetium Tc 99m decays by isomeric transition with a physical half-life of 6 hours. The principal photon that is useful for detection and imaging studies is listed in Table 7 . Table 7 Principal Radiation Emission Data Radiation Mean % per Disintegration Mean Energy (keV) Gamma-2 88.5 140.5 The air-kerma-rate (exposure-rate) constant for Technetium Tc 99m is 5.23 m 2 ·pGy·(MBq) − 1 ·s − 1 [0.795 cm 2 ·R·(mCi) − 1 ·h − 1 ]. A range of values for the relative radiation attenuation by the various thicknesses of lead is shown in Table 8 . For example, the use of a 3 mm thickness of lead will attenuate the radiation emitted by a factor of about 1,000. Table 8 Radiation Attenuation by Lead Shielding Shield Thickness (Pb) cm Coefficient of Attenuation 0.25 0.5 1 10 -1 2 10 -2 3 10 -3 4 10 -4 To correct for physical decay of this radionuclide, the fractions that remain at selected intervals after the time of calibration are shown in Table 9 . Table 9 Physical Decay Chart of Technetium 99m Tc, Half Life: 6 Hours *Calibration Time Hours Fraction Remaining Hours Fraction Remaining 0 * 1.000 5 0.562 1 0.891 6 0.501 2 0.794 8 0.398 3 0.708 10 0.316 4 0.631 12 0.251

Kit for the Preparation of Technetium Tc 99m Pentetate KIT FOR THE PREPARATION OF TECHNETIUM TC 99M PENTETATE
CURIUM US LLC FDA Rx Only

11.1 Chemical Characteristics Kit for the Preparation of Technetium Tc 99m pentetate injection, a radioactive diagnostic agent, for intravenous or inhalation use. Each multiple-dose 10 mL glass vial contains a sterile, non-pyrogenic, non-radioactive lyophilized powder of 20 mg of pentetic acid, 5 mg of p-aminobenzoic acid, 3.73 mg of calcium chloride dihydrate, and not less than 0.25 mg stannous chloride dihydrate and not more than 0.385 mg maximum tin expressed as stannous chloride dihydrate. The lyophilized product is sealed under an atmosphere of nitrogen. No bacteriostatic preservative is present. Its chemical name is: Technetate (1-)99mTc,[N,N-bis[2-[bis(carboxymethyl)amino]ethyl]-glycinato(5-)]-, sodium. The structure of the technetium labeled form is: The pH is adjusted with HCl and/or NaOH prior to lyophilization so that the pH range of the reconstituted radiopharmaceutical is 6.5 to 7.5. image description 11.2 Physical Characteristics Technetium Tc 99m decays by isomeric transition with a physical half-life of 6 hours. The principal photon that is useful for detection and imaging studies is listed in Table 7 . Table 7 Principal Radiation Emission Data Radiation Mean % per Disintegration Mean Energy (keV) Gamma-2 88.5 140.5 The air-kerma-rate (exposure-rate) constant for Technetium Tc 99m is 5.23m 2 ·pGy·(MBq) -1 ·s -1 [0.795cm 2 ·R·(mCi) -1 ·h -1 ]. A range of values for the relative radiation attenuation by the various thicknesses of lead is shown in Table 8 . For example, the use of a 3 mm thickness of lead will attenuate the radiation emitted by a factor of about 1,000. Table 8 Radiation Attenuation by Lead Shielding Shield Thickness (Pb) mm Coefficient of Attenuation 0.25 0.5 1 10 -1 2 10 -2 3 10 -3 4 10 -4 To correct for physical decay of this radionuclide, the fractions that remain at selected intervals after the time of calibration are shown in Table 9 . Table 9 Physical Decay Chart of Technetium 99m Tc, Half Life: 6 Hours Hours Fraction Remaining Hours Fraction Remaining 0* 1.000 5 0.562 1 0.891 6 0.501 2 0.794 8 0.398 3 0.708 10 0.316 4 0.631 12 0.251 *Calibration Time

About kit for the preparation of technetium tc 99m pentetate Generic Drugs

This collection groups medications in our database under the generic name kit for the preparation of technetium tc 99m pentetate. It currently includes 2 matching listings. Open any result to review brand context, dosage forms, ingredients, and label-backed details.

What You Can Review

Use this page to compare the set of products we have indexed for this generic name. Each result links to more detailed product information and related landing pages.

Safety Information

Always consult a qualified healthcare professional before starting, stopping, or switching any medication. The information on this page is educational and should not replace medical advice.