COMPRESSED Gas OXIDIZING, N.O.S. OXYGEN HELIUM NORCO, INC. FDA Approved No description available yet.
FunFoxMeds box
Substance Helium
Route
RESPIRATORY (INHALATION)

Drug Facts

Composition & Profile

Quantities
83507 count

Identifiers & Packaging

Container Type UNKNOWN
UNII
206GF3GB41 S88TT14065
Packaging

COMPRESSED GAS OXIDIZING, N.O.S. LABEL 30% OXYGEN USP BALANCE HELIUM, USP NON-FLAMMABLE GAS 2 OXIDIZER 5.1 Compressed gas, oxidizing, n.o.s. (Oxygen, Helium) UN 3156 SPG TCMD3 Part Number ___________________________________________________________________________ Medical Gas Mixture 30% Oxygen, USP CAS: 7782-44-7 Balance Heliun, USP CAS: 7440-59-7 ___________________________________________________________________________ Rx only WARNING: Administration of this gas mixture may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of gas mixtures and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications and side effects and the precautions to be taken. DANGER: CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52 degrees C (125 degrees F). Read and follow the Safety Data Sheet (SDS) before use. FIRST AID: IF ACCIDENTALLY INHALED; Remove to fresh air and keep comfortable for breathing. Get medical advice/attention. ___________________________________________________________________________________________________ Lot No: x-xxx-xxx – Volume 300 NorLAB In Emergency Call: 1-800-424-9300 Serial Number: T-113017 To Order Call: 800-657-6672 NorLab SPG TCMD3 Part Numbe 898 W. Gowen Rd., Boise, ID 83507 898 W. Gowen Road Boise, ID 83507 800-657-6572 res UN 3156 HeliOx 30

Package Descriptions
  • COMPRESSED GAS OXIDIZING, N.O.S. LABEL 30% OXYGEN USP BALANCE HELIUM, USP NON-FLAMMABLE GAS 2 OXIDIZER 5.1 Compressed gas, oxidizing, n.o.s. (Oxygen, Helium) UN 3156 SPG TCMD3 Part Number ___________________________________________________________________________ Medical Gas Mixture 30% Oxygen, USP CAS: 7782-44-7 Balance Heliun, USP CAS: 7440-59-7 ___________________________________________________________________________ Rx only WARNING: Administration of this gas mixture may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of gas mixtures and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications and side effects and the precautions to be taken. DANGER: CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52 degrees C (125 degrees F). Read and follow the Safety Data Sheet (SDS) before use. FIRST AID: IF ACCIDENTALLY INHALED; Remove to fresh air and keep comfortable for breathing. Get medical advice/attention. ___________________________________________________________________________________________________ Lot No: x-xxx-xxx – Volume 300 NorLAB In Emergency Call: 1-800-424-9300 Serial Number: T-113017 To Order Call: 800-657-6672 NorLab SPG TCMD3 Part Numbe 898 W. Gowen Rd., Boise, ID 83507 898 W. Gowen Road Boise, ID 83507 800-657-6572 res UN 3156 HeliOx 30

Overview

No description available yet.

Dosage & Administration

Not available

Warnings & Precautions
No warnings available yet.

Similar Drugs

Related medications based on brand, generic name, substance, active ingredients.

View all similar drugs →