16 HOW SUPPLIED Ammonia N 13 Injection, USP is packaged in 30 mL multiple dose glass vial containing between 1.11 GBq to 11.1 GBq (30 mCi to 300 mCi) of [13N] ammonia, at the end of synthesis (EOS) reference time, in 0.9% sodium chloride injection solution in approximately 10 mL volume. The recommended dose of radioactivity (10 mCi – 20 mCi) is associated with a theoretical mass dose of 0.5-1.0 picomoles of Ammonia. NDC 73410-001-01 Storage Store at 25°C (77°F); excursions permitted to 15-30°C (59-86°F). Use the solution within 60 minutes of the End of Synthesis (EOS) calibration.; PRINCIPAL DISPLAY PANEL - Vial Label Ammonia N 13 Injection, USP For Intravenous Use 3.75 mCi/mL to 37.5 mCi/mL @ EOS* Lot #: Rx Only NDC# 73410-001-01 Sterile, Non-pyrogenic. Contains 0.138 GBq to 1.387 GBq (3.75 mCi/mL to 37.5 mCi/mL) @ EOS* of no-carrier added Ammonia N13 injection in 0.9% NaCl. Multi-Dose Vial Diagnostic - For Intravenous Use Only. Store @ 25°C (77°F); See Insert. Store upright in shielded container. Aseptically withdraw/handle doses. *EOS - End of Synthesis. Expires 60 minutes after EOS. Calculate correct dosage from date and time of calibration. Do not use if cloudy or contains particulate matter. (N13) Half-life = 9.96 minutes. Manufactured by: SOFIE Co. dba SOFIE Dules, VA 20166 Caution: Radioactive Material Label
- 16 HOW SUPPLIED Ammonia N 13 Injection, USP is packaged in 30 mL multiple dose glass vial containing between 1.11 GBq to 11.1 GBq (30 mCi to 300 mCi) of [13N] ammonia, at the end of synthesis (EOS) reference time, in 0.9% sodium chloride injection solution in approximately 10 mL volume. The recommended dose of radioactivity (10 mCi – 20 mCi) is associated with a theoretical mass dose of 0.5-1.0 picomoles of Ammonia. NDC 73410-001-01 Storage Store at 25°C (77°F); excursions permitted to 15-30°C (59-86°F). Use the solution within 60 minutes of the End of Synthesis (EOS) calibration.
- PRINCIPAL DISPLAY PANEL - Vial Label Ammonia N 13 Injection, USP For Intravenous Use 3.75 mCi/mL to 37.5 mCi/mL @ EOS* Lot #: Rx Only NDC# 73410-001-01 Sterile, Non-pyrogenic. Contains 0.138 GBq to 1.387 GBq (3.75 mCi/mL to 37.5 mCi/mL) @ EOS* of no-carrier added Ammonia N13 injection in 0.9% NaCl. Multi-Dose Vial Diagnostic - For Intravenous Use Only. Store @ 25°C (77°F); See Insert. Store upright in shielded container. Aseptically withdraw/handle doses. *EOS - End of Synthesis. Expires 60 minutes after EOS. Calculate correct dosage from date and time of calibration. Do not use if cloudy or contains particulate matter. (N13) Half-life = 9.96 minutes. Manufactured by: SOFIE Co. dba SOFIE Dules, VA 20166 Caution: Radioactive Material Label
Overview
11.1 Chemical Characteristics Ammonia N 13 Injection, USP is a positron emitting radiopharmaceutical that is used for diagnostic purposes in conjunction with positron emission tomography (PET) imaging. The active ingredient, [13 N] ammonia, has the molecular formula of 13NH3 with a molecular weight of 16.02, and has the following chemical structure: Ammonia N 13 Injection is provided as a ready to use sterile, pyrogen-free, clear and colorless solution. Each mL of the solution contains between 0.138 GBq to 1.387 GBq (3.75 mCi to 37.5 mCi) of [13N] ammonia, at the end of synthesis (EOS) reference time, in 0.9% aqueous sodium chloride. The pH of the solution is between 4.5 to 7.5. The recommended dose of radioactivity (10-20 mCi) is associated with a theoretical mass dose of 0.5-1.0 picomoles of ammonia. Molecule 11.2 Physical Characteristics Nitrogen N13 decays by emitting positron to Carbon C13 (stable) and has a physical half-life of 9.96 minutes. The principal photons useful for imaging are the dual 511 keV gamma photons that are produced and emitted simultaneously in opposite direction when the positron interacts with an electron ( Table 2 ). Table 2. Principal Radiation Emission Data for Nitrogen 13 * Produced by positron annihilation Radiation/Emission % Per Disintegration Energy Positron(β+) 100 1190 keV (Max.) Gamma (±)* 200 511.0 keV The specific gamma ray constant (point source air kerma coefficient) for nitrogen N 13 is 5.9 R/hr/mCi (1.39 x 10 ‑6 Gy/hr/kBq) at 1 cm. The half-value layer (HVL) of lead (Pb) for 511 keV photons is 4 mm. Selected coefficients of attenuation are listed in Table 3 as a function of lead shield thickness. For example, the use of 39 mm thickness of lead will attenuate the external radiation by a factor of about 1000. Table 3. Radiation Attenuation of 511keV Photons by lead (Pb) shielding Shield thickness (Pb) mm Coefficient of attenuation 4 0.50 8 0.25 13 0.10 26 0.01 39 0.001 52 0.0001 Table 4 lists fractions remaining at selected time intervals from the calibration time. This information may be used to correct for physical decay of the radionuclide. Table 4. Physical Decay Chart for Nitrogen 13 * calibration time Minutes Fraction Remaining 0* 1.000 5 0.706 10 0.499 15 0.352 20 0.249 25 0.176 30 0.124
Indications & Usage
Ammonia N 13 Injection, USP is indicated for diagnostic Positron Emission Tomography (PET) imaging of the myocardium under rest or pharmacologic stress conditions to evaluate myocardial perfusion in patients with suspected or existing coronary artery disease. Ammonia N 13 Injection, USP is a radioactive diagnostic agent for Positron Emission Tomography (PET) indicated for diagnostic PET imaging of the myocardium under rest or pharmacologic stress conditions to evaluate myocardial perfusion in patients with suspected or existing coronary artery disease ( 1 ).
Dosage & Administration
Rest Imaging Study ( 2.1 ): Aseptically withdraw Ammonia N 13 Injection from its container and administer 10 mCi—20 mCi (0.368 GBq—0.736 GBq) as a bolus through a catheter inserted into a large peripheral vein. Start imaging 3 minutes after the injection and acquire images for a total of 10-20 minute Stress Imaging Study ( 2.2 ): If a rest imaging study is performed, begin the stress imaging study 40 minutes or more after the first Ammonia N 13 injection to allow for sufficient isotope decay. Administer a pharmacologic stress-inducing drug in accordance with its labeling. Aseptically withdraw Ammonia N 13 Injection from its container and administer 10 mCi—20 mCi (0.368 GBq—0.736 GBq) of Ammonia N 13 Injection as a bolus at 8 minutes after the administration of the pharmacologic stress-inducing drug. Start imaging 3 minutes after the Ammonia N 13 Injection and acquire images for a total of 10-20 minutes. Patient Preparation ( 2.3 ): To increase renal clearance of radioactivity and to minimize radiation dose to the bladder, hydrate the patient before the procedure and encourage voiding as soon as each image acquisition is completed and as often as possible thereafter for at least one hour. 2.1 Rest Imaging Study Aseptically withdraw Ammonia N 13 Injection from its container and administer 10 mCi-20 mCi (0.368 GBq-0.736 GBq) as a bolus through a catheter inserted into a large peripheral vein. Start imaging 3 minutes after the injection and acquire images for a total of 10-20 minutes. 2.2 Stress Imaging Study If a rest imaging study is performed, begin the stress imaging study 40 minutes or more after the first Ammonia N 13 injection to allow sufficient isotope decay. Administer a pharmacologic stress-inducing drug in accordance with its labeling. Aseptically withdraw Ammonia N 13 Injection from its container and administer 10 mCi—20 mCi (0.368 GBq—0.736 GBq) of Ammonia N 13 Injection as a bolus at 8 minutes after the administration of the pharmacologic stress-inducing drug. Start imaging 3 minutes after the Ammonia N 13 Injection and acquire images for a total of 10-20 minutes. 2.3 Patient Preparation To increase renal clearance of radioactivity and to minimize radiation dose to the bladder, ensure that the patient is well hydrated before the procedure and encourage voiding as soon as a study is completed and as often as possible thereafter for at least one hour. 2.4 Radiation Dosimetry The converted radiation absorbed doses in rem/mCi are shown in Table 1 . These estimates are calculated from the Task Group of Committee 2 of the International Commission on Radiation Protection. Table 1. N13 Absorbed Radiation Dose Per Unit Activity (rem/mCi) for Adults and Pediatric Groups Organ Age (Years) Adult 15 10 5 1 * Upper large intestine, ** Lower large intestine Adrenals 0.0085 0.0096 0.016 0.025 0.048 Bladder Wall 0.030 0.037 0.056 0.089 0.17 Bone Surfaces 0.0059 0.0070 0.011 0.019 0.037 Brain 0.016 0.016 0.017 0.019 0.027 Breast 0.0067 0.0067 0.010 0.017 0.033 Stomach Wall 0.0063 0.0078 0.012 0.019 0.037 Small Intestine 0.0067 0.0081 0.013 0.021 0.041 *ULI 0.0067 0.0078 0.013 0.021 0.037 **LLI 0.0070 0.0078 0.013 0.020 0.037 Heart 0.0078 0.0096 0.015 0.023 0.041 Kidneys 0.017 0.021 0.031 0.048 0.089 Liver 0.015 0.018 0.029 0.044 0.085 Lungs 0.0093 0.011 0.018 0.029 0.056 Ovaries 0.0063 0.0085 0.014 0.021 0.041 Pancreas 0.0070 0.0085 0.014 0.021 0.041 Red Marrow 0.0063 0.0078 0.012 0.020 0.037 Spleen 0.0093 0.011 0.019 0.030 0.056 Testes 0.0067 0.0070 0.011 0.018 0.035 Thyroid 0.0063 0.0081 0.013 0.021 0.041 Uterus 0.0070 0.0089 0.014 0.023 0.041 Other Tissues 0.0059 0.0070 0.011 0.018 0.035 2.5 Drug Handling Inspect Ammonia N 13 Injection visually for particulate matter and discoloration before administration, whenever solution and container permit. Do not administer Ammonia N 13 Injection containing particulate matter or discoloration; dispose of these unacceptable or unused preparations in a safe manner, in compliance with applicable regulations. Wear waterproof gloves and effective shielding when handling Ammonia N 13 Injection. Use aseptic technique to maintain sterility during all operation involved in the manipulation and administration of Ammonia N 13 Injection. The contents of each vial are sterile and non-pyrogenic. Use appropriate safety measures, including shielding, consistent with proper patient management to avoid unnecessary radiation exposure to the patient, occupational workers, clinical personnel, and other persons. Radiopharmaceuticals should be used by or under the control of physicians who are qualified by specific training and experience in the safe use and handling of radionuclides, and whose experience and training have been approved by the appropriate governmental agency authorized to license the use of radionuclides. Before administration of Ammonia N 13 Injection, assay the dose in a properly calibrated dose calibrator.
Warnings & Precautions
Ammonia N 13 Injection may increase the risk of cancer. Use the smallest dose necessary for imaging and ensure safe handling to protect the patient and health care worker ( 5.1 ). 5.1 Radiation Risks Ammonia N 13 Injection may increase the risk of cancer. Use the smallest dose necessary for imaging and ensure safe handling to protect the patient and health care worker [see Dosage and Administration ( 2.4 )] .
Contraindications
None. None ( 4 ).
Adverse Reactions
No adverse reactions have been reported for Ammonia N 13 Injection based on a review of the published literature, publicly available reference sources, and adverse drug reaction reporting systems. However, the completeness of these sources is not known. No adverse reactions have been reported for Ammonia N 13 Injection based on a review of the published literature, publicly available reference sources, and adverse drug reaction reporting system ( 6 ). To report SUSPECTED ADVERSE REACTIONS, contact SOFIE Co. at 800-207-1865 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.
Drug Interactions
The possibility of interactions of Ammonia N 13 Injection with other drugs taken by patients undergoing PET imaging has not been studied.
Similar Drugs
Related medications based on brand, generic name, substance, active ingredients.