Messer Llc - Nitrogen Nf Bulk Liquid

Messer Llc - Nitrogen Nf Bulk Liquid
SPL v21
SPL
SPL Set ID c6f2772a-e53a-c379-b99e-a4f7c3e82f60
Route
RESPIRATORY (INHALATION)
Published
Effective Date 2025-11-11
Document Type 34391-3 HUMAN PRESCRIPTION DRUG LABEL

Drug Facts

Composition & Product

Active Ingredients
Nitrogen (995 mL)

Identifiers & Packaging

Marketing Status
NDA Active Since 1960-01-01

Description

Plant 123 Messer St, Anytown, USA Certificate of Analysis - Stall 1 Product: Nitrogen NF Date: 10/27/2025 Lot#: 5138-1-1992-102725-04 Tare Weight: 31800 lbs. Gross Weight: 48500 lbs. Net Weight: 16700 lbs. Net Volume: 230.51 kscf Batch #: AIT-81-6-102725-01 Logon Time: 2025-10-27 11:17:42 Analysis Finish: 2025-10-27 11:30:18 Logoff Time: 2025-10-27 11:31:57 Final Analysis Results Analyzer # Test/Units LIN1 Specs Analysis Results Limit of Detection Organoleptic Odor None None AIT-81-6 PPM O₂ ≤ 5.00 1.14 0.10 AIT-81-2 PPM CO ≤ 10.00 0.35 0.10 LAB PPM CO₂ N/A NT 0.10 AIT-81-4A PPM H₂O N/A NT 0.10 AIT-80-2A PPM THC N/A NT 0.10 LAB PPM H₂ N/A NT 0.20 Assay Results (by difference) Nitrogen Min % ≥ 99.0 (Messer Spec ≥ 99.999%) 99.99985 NT = Not Tested PPM O₂ Method Used: Electrochemical   Manufacturer/Model#: Teledyne 3000TA-XL PPM CO Method Used: Infrared   Manufacturer/Model#: Siemens Ultramat 6 These analyzers have been validated by Messer as acceptable alternatives to the official NF for Nitrogen Assay. Validation study documentation is maintained by Messer at the corporate office. LIN NDA: 205766, LIN NADA: 14136 This document contains an electronic signature. Analyst Date Sample Results Obtained from Messer Validated Analyzers 10/27/2025 Quality Reviewer Date John Doe 10/27/2025 Should the material not be delivered to an NF customer, the material is "Not Approved for Human Drug Use" LOX1


Medication Information

Description

Plant 123 Messer St, Anytown, USA Certificate of Analysis - Stall 1 Product: Nitrogen NF Date: 10/27/2025 Lot#: 5138-1-1992-102725-04 Tare Weight: 31800 lbs. Gross Weight: 48500 lbs. Net Weight: 16700 lbs. Net Volume: 230.51 kscf Batch #: AIT-81-6-102725-01 Logon Time: 2025-10-27 11:17:42 Analysis Finish: 2025-10-27 11:30:18 Logoff Time: 2025-10-27 11:31:57 Final Analysis Results Analyzer # Test/Units LIN1 Specs Analysis Results Limit of Detection Organoleptic Odor None None AIT-81-6 PPM O₂ ≤ 5.00 1.14 0.10 AIT-81-2 PPM CO ≤ 10.00 0.35 0.10 LAB PPM CO₂ N/A NT 0.10 AIT-81-4A PPM H₂O N/A NT 0.10 AIT-80-2A PPM THC N/A NT 0.10 LAB PPM H₂ N/A NT 0.20 Assay Results (by difference) Nitrogen Min % ≥ 99.0 (Messer Spec ≥ 99.999%) 99.99985 NT = Not Tested PPM O₂ Method Used: Electrochemical   Manufacturer/Model#: Teledyne 3000TA-XL PPM CO Method Used: Infrared   Manufacturer/Model#: Siemens Ultramat 6 These analyzers have been validated by Messer as acceptable alternatives to the official NF for Nitrogen Assay. Validation study documentation is maintained by Messer at the corporate office. LIN NDA: 205766, LIN NADA: 14136 This document contains an electronic signature. Analyst Date Sample Results Obtained from Messer Validated Analyzers 10/27/2025 Quality Reviewer Date John Doe 10/27/2025 Should the material not be delivered to an NF customer, the material is "Not Approved for Human Drug Use" LOX1

Section 51945-4

Plant

123 Messer St, Anytown, USA

Certificate of Analysis - Stall 1

Product: Nitrogen NF

Date: 10/27/2025

Lot#: 5138-1-1992-102725-04

Tare Weight: 31800 lbs.

Gross Weight: 48500 lbs.

Net Weight: 16700 lbs.

Net Volume: 230.51 kscf

Batch #: AIT-81-6-102725-01

Logon Time: 2025-10-27 11:17:42

Analysis Finish: 2025-10-27 11:30:18

Logoff Time: 2025-10-27 11:31:57

Final Analysis Results

Analyzer #

Test/Units

LIN1 Specs

Analysis Results

Limit of Detection

Organoleptic

Odor

None

None

AIT-81-6

PPM O₂

≤ 5.00

1.14

0.10

AIT-81-2

PPM CO

≤ 10.00

0.35

0.10

LAB

PPM CO₂

N/A

NT

0.10

AIT-81-4A

PPM H₂O

N/A

NT

0.10

AIT-80-2A

PPM THC

N/A

NT

0.10

LAB

PPM H₂

N/A

NT

0.20

Assay Results (by difference)

Nitrogen Min %

≥ 99.0 (Messer Spec ≥ 99.999%)

99.99985

NT = Not Tested

PPM O₂ Method Used: Electrochemical   Manufacturer/Model#: Teledyne 3000TA-XL

PPM CO Method Used: Infrared   Manufacturer/Model#: Siemens Ultramat 6

These analyzers have been validated by Messer as acceptable alternatives to the official NF for Nitrogen Assay. Validation study documentation is maintained by Messer at the corporate office. LIN NDA: 205766, LIN NADA: 14136

This document contains an electronic signature.

Analyst

Date

Sample Results Obtained from Messer Validated Analyzers

10/27/2025

Quality Reviewer

Date

John Doe

10/27/2025

Should the material not be delivered to an NF customer, the material is "Not Approved for Human Drug Use"

LOX1


Structured Label Content

Section 51945-4 (51945-4)

Plant

123 Messer St, Anytown, USA

Certificate of Analysis - Stall 1

Product: Nitrogen NF

Date: 10/27/2025

Lot#: 5138-1-1992-102725-04

Tare Weight: 31800 lbs.

Gross Weight: 48500 lbs.

Net Weight: 16700 lbs.

Net Volume: 230.51 kscf

Batch #: AIT-81-6-102725-01

Logon Time: 2025-10-27 11:17:42

Analysis Finish: 2025-10-27 11:30:18

Logoff Time: 2025-10-27 11:31:57

Final Analysis Results

Analyzer #

Test/Units

LIN1 Specs

Analysis Results

Limit of Detection

Organoleptic

Odor

None

None

AIT-81-6

PPM O₂

≤ 5.00

1.14

0.10

AIT-81-2

PPM CO

≤ 10.00

0.35

0.10

LAB

PPM CO₂

N/A

NT

0.10

AIT-81-4A

PPM H₂O

N/A

NT

0.10

AIT-80-2A

PPM THC

N/A

NT

0.10

LAB

PPM H₂

N/A

NT

0.20

Assay Results (by difference)

Nitrogen Min %

≥ 99.0 (Messer Spec ≥ 99.999%)

99.99985

NT = Not Tested

PPM O₂ Method Used: Electrochemical   Manufacturer/Model#: Teledyne 3000TA-XL

PPM CO Method Used: Infrared   Manufacturer/Model#: Siemens Ultramat 6

These analyzers have been validated by Messer as acceptable alternatives to the official NF for Nitrogen Assay. Validation study documentation is maintained by Messer at the corporate office. LIN NDA: 205766, LIN NADA: 14136

This document contains an electronic signature.

Analyst

Date

Sample Results Obtained from Messer Validated Analyzers

10/27/2025

Quality Reviewer

Date

John Doe

10/27/2025

Should the material not be delivered to an NF customer, the material is "Not Approved for Human Drug Use"

LOX1


Advanced Ingredient Data


Raw Label Data

All Sections (JSON)