Dry Eye Test
04866053-f973-471e-b3bc-241fb76303a2
34391-3
HUMAN PRESCRIPTION DRUG LABEL
Drug Facts
Composition & Product
Identifiers & Packaging
Description
Dry Eye Test Fluorescein Sodium Ophthalmic Strips U.S.P. diagnostic agent is for professional use only Each strip is impregnated with 0.12 mg of fluorescein sodium USP.
How Supplied
Carton of 50 pouches of two strips each.
Medication Information
Contraindications
Hypersensitivity to components or mercury-containing compounds.
How Supplied
Carton of 50 pouches of two strips each.
Description
Dry Eye Test Fluorescein Sodium Ophthalmic Strips U.S.P. diagnostic agent is for professional use only Each strip is impregnated with 0.12 mg of fluorescein sodium USP.
Section 42229-5
Dry Eye Test Fluorescein Sodium Ophthalmic Strips U.S.P. diagnostic agent is for professional use only
Each strip is impregnated with 0.12 mg of fluorescein sodium USP.
Indications
For testing tear film stability by determining the fluorescein break-up time (FBUT).
Directions for Use
Procedure for measuring Fluorescein
Break-up Time (FBUT) with Amcon Dry Eye Test Strips.
1. Apply one or two drops of non-preserved saline to the
impregnated paper tip. Excess fluid will automatically fall off.
Shaking is neither
required nor desirable.
2. Ask the patient to look down and in.
3. Gently touch the strip to the superior temporal bulbar conjunctiva
for one or two seconds.
4. Ask the patient to blink three times and open eyes naturally.
5. Conduct the FBUT measurements immediately.
6. Perform two consecutive measurements. If not consistent, conduct
a third and average the results.
7. Repeat steps 1 through 6 using a new strip for the second eye
FBUT values of less than 10 seconds are considered abnormal. Values less than 5 seconds are indicative of dry eye disorder. Values of 5 to 9 seconds are borderline dry eye.
Principal Display Panel 100 Sterile Strips (50 Pouches of 2 Strips Each)
Structured Label Content
Contraindications (34070-3)
Hypersensitivity to components or mercury-containing compounds.
Section 42229-5 (42229-5)
Dry Eye Test Fluorescein Sodium Ophthalmic Strips U.S.P. diagnostic agent is for professional use only
Each strip is impregnated with 0.12 mg of fluorescein sodium USP.
Indications (INDICATIONS)
For testing tear film stability by determining the fluorescein break-up time (FBUT).
How Supplied (HOW SUPPLIED)
Carton of 50 pouches of two strips each.
Directions for Use (DIRECTIONS FOR USE)
Procedure for measuring Fluorescein
Break-up Time (FBUT) with Amcon Dry Eye Test Strips.
1. Apply one or two drops of non-preserved saline to the
impregnated paper tip. Excess fluid will automatically fall off.
Shaking is neither
required nor desirable.
2. Ask the patient to look down and in.
3. Gently touch the strip to the superior temporal bulbar conjunctiva
for one or two seconds.
4. Ask the patient to blink three times and open eyes naturally.
5. Conduct the FBUT measurements immediately.
6. Perform two consecutive measurements. If not consistent, conduct
a third and average the results.
7. Repeat steps 1 through 6 using a new strip for the second eye
FBUT values of less than 10 seconds are considered abnormal. Values less than 5 seconds are indicative of dry eye disorder. Values of 5 to 9 seconds are borderline dry eye.